Contrex CX-1102 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Czujniki Contrex CX-1102. CONTREX CX-1102 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - STARTUP GUIDE

SK1676 Rev ACX-1102STARTUP GUIDE

Strona 2

Page 8DANGERMotion will occur in the calibration procedure.It is possible that sudden/violent motion couldresult and cause damage or personal injury.M

Strona 3 - INTRODUCTION

Page 9DANGERHazardous voltages.Can cause severeinjury, death ordamagethe equipment.Make adjustmentswith caution.

Strona 4

Page 10Step 1 - Application Configuration - Parameter EntryClose the "Setup" input. The CX-1102 will change to "Setup State" and

Strona 5

Page 11Step 3 - Wind Roll Setup - Parameter EntryThe CX-1102 will display System Setup Wind Roll\Page 3.Setup State {MP-59} will equal 2.Configure the

Strona 6 - BASIC WIRING

Page 12Step 5 - Signal Polarity TestThe CX-1102 will display System Setup Signal Polarity\Page 5. Setup State {MP-59} will equal 4.Setup State {MP-59

Strona 7 - (50V MAX)

Page 13Fail test: The CX-1102 will flash "Wind Failure" then "Pg Up" in the bottom center of the display.Check the following:a. C

Strona 8 - OPERATOR INTERFACE PRIMER

Page 14 The CX-1102 will change the UwndEncPty {CP-264} to match the control output signal based on the recorded information. For unipolar drives,

Strona 9 - CX-1102 Operator Interface

Page 15Step 6 - Dancer CalibrationThe CX-1102 will display automatically System Setup Dancer\Page 6. Setup State {MP-59} will equal 6.Setup State {MP

Strona 10 - SYSTEM SETUP PROCEDURE

Page 16Step 7 - Wind Direction TestThe CX-1102 will display automatically System Setup Wind Direction\Page 7.Setup State {MP-59} will equal 8.Setup St

Strona 11

Page 17If the dancer moves from Full to approximately 3/4 of Full, the Wind roll is stopped, the Dancer willbe held in position, and the test Passes.F

Strona 13

Page 18Step 8 - Unwind Direction TestThe CX-1102 will display automatically System Setup Unwind Direction\Page 8.Setup State {MP-59} will equal 9.Setu

Strona 14 - Alert everyone present

Page 19If UwndCO Mode {CP-280} is set to Unipolar, this test Fails.If UwndCO Mode {CP-280} is set to Bipolar or Unipolar Reversing, UwndCOPolarity {CP

Strona 15

Page 20—NOTES—

Strona 16

Page 21—NOTES—

Strona 17 - Step 6 - Dancer Calibration

Page 22CONTREX, INC.8900 Zachary Lane NorthMaple Grove, MN 55369 USA Phone:763.424.7800Fax: [email protected]

Strona 18 - Step 7 - Wind Direction Test

Page 1INTRODUCTIONThe CX-1102 motion controller is used with various types of motor drives for precision control of unwind/wind applications. The typ

Strona 19 - End of Wind Direction Test

Page 2• Dancer Electrical Design: The analog electrical signal from the dancer should be stable, repeatable,noise-free, and linear with respect to da

Strona 20

Page 3—NOTES—

Strona 21 - End of Unwind Direction Test

Page 4BASIC WIRINGWARNINGThe CX-1102 should only be installed by a qualified electrician.Hazardous voltages may cause severe injury, death or equipmen

Strona 22

Page 5+5VDC DncrLnSpd Com1234JASigU ComU12J3SigW ComW12J8TD/RD + TD/RD -Com123J1+V_DO UwdEnWdEn UErr WErr WRlFlDncrWbBrkSpareCom123 4 5 6 7 8 9 10J2L1

Strona 23

Page 6OPERATOR INTERFACE PRIMERThe remainder of the CX-1102 setup procedure involves setting control parameter values through the operator interface,a

Strona 24

Page 7CX-1102 Operator Interface741-8956230.CLEARENTERMENUSTATUSCODEHELPCONTREXSETUPSCALINGSETPOINTS & RAMPSTUNINGALARMS & LIMITSBLOCKSPLCSYST

Komentarze do niniejszej Instrukcji