MP-53 CONTROL STATE
Control State (MP-53 ) displays a number “1” to indicate the active control state of the
ML–Drive. In the example below, “Run” is the active control state.
Jog
Run
R-Stop
F-Stop
Code
MP-54 LOGIC INPUTS - GROUP A
The Logic Inputs - Group A (MP-54) displays the status of the Run, Jog, R–Stop and F–Stop
logic inputs. The number “1” indicates an open, or logic high level. The number “0” indicates a
closed, or logic low level (shorted to common). In the example below, “Jog” is the open or logic
high level.
Run (J4 Pin 6)
Jog (J4 Pin 7)
R–Stop (J4 Pin 9)
F–Stop (J4 Pin 10)
Code