Contrex ML-Drive Instrukcja Użytkownika Strona 70

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 69
3 - 36
Jog has the least operating priority. Jog ramps to the Jog Setpoint (CP-05), using the
Acceleration Time (CP-16). When Jog is terminated, the ML-Drive brings the drive
output to an immediate Zero. Unlike the other inputs, Jog is not latched and must be
sustained to remain active.
To activate Jog:
Short the F–Stop and R–Stop inputs to common.
Open the Run input.
Short the Jog input to common. (Jog must be sustained to remain active).
R-STOP
F-STOP
RUN
JOG
COMMON
R-STOP
F-STOP
COMMON
JOG
RUN
Maintain Closed
6
7
8
9
10
11
J4
Przeglądanie stron 69
1 2 ... 65 66 67 68 69 70 71 72 73 74 75 ... 177 178

Komentarze do niniejszej Instrukcji

Brak uwag