2 - 11
Figure 2-11 F–Stop
F-Stop (J6 pins 7, 8)
F-Stop is a momentary input. When
it is open, the MLP–Trim stops
immediately (zero RPM) and ignores
the specified deceleration rate. As a
momentary input, F-Stop is internally
latched and does not need to be
maintained by an operator device.
Master / Follower
(J6 pins 9, 13)
This input determines the MLP–
Trim's mode of operation and
resulting scaling formula that the
control algorithm uses. The MLP–
Trim is in Master mode when the
circuit is open, and Follower or Offset
mode if the circuit is shorted to the
common.
Figure 2-12 Master / Follower
MASTER
9
13
J6
FOLLOWER
F-STOP
7
8
J6